  Datasheet File OCR Text:
 PCL-725
Features
8-ch Relay and 8-ch Isolated Digital Input ISA Card
8 x relay output channels and 8 x isolated digital input channels LED indicators to show activated relays 4 x Form C and 4 x Form A type relay output channels Male DB37 matching connector included Output status readback
RoHS
2002/95/EC
COMPLIANT
Introduction
The PCL-725 relay actuator and isolated digital input card offers 8 relay actuators and 8 opto-isolated digital inputs on a single board.Typically, the onboard relays can serve as on/off control devices or small power switches. The 8 x opto-isolated DI channels are ideal devices for collecting digital inputs under noisy environment or floating potential. Also, the 8 x isolated inputs provide the best method to prevent any ground loop problems. For easy monitoring, each relay is equipped with one red LED to reflect its on/off status. Each input channel is jumper selectable to either isolated or non-isolated input. Access to input and output channels is made possible through an onboard 37-pin D type connector.
Specifications
Isolated Digital Input
Channels Input Voltage Isolation Protection Input Resistance Input Current 8 5 ~ 24 VDC 1,500 VDC 560 W 60 mA max.
General
ISA 1 x DB37 female connector 147 x 100 mm (5.75" x 3.9") +5 V @ < 0.2 A; +12 V @ 33 mA for each relay < 0.27 A if all eight relays are energized Operating Temperature 0 ~ 60 C (32 ~ 140 F) (IEC 68-2-1, 2) Storage Temperature -20 ~ 70 C (-4 ~ 158 F) Storage Humidity 5 ~ 95 % RH, non-condensing (IEC 68-2-3) Bus Type I/O Connectors Dimensions (L x H) Power Consumption
Non-isolated Digiteal Input
Channels Input Voltage 8 (Jumper-selectable) Logic 0: 0.8 V max. Logic 1: 2.0 V min. (5.25 V max.)
Ordering Information
PCL-725 PCL-10137-1 PCL-10137-2 PCL-10137-3 ADAM-3937 PCLD-880 8-ch Relay/Isolated Digital Input ISA Card DB37 Cable, 1 m DB37 Cable, 2 m DB37 Cable, 3 m DB37 DIN-rail Wiring Board Wiring Board w/ Two 20-pin Flat Cables & Adapter
Relay Output
Channels Relay Type Contact Rating Relay on Time Relay off Time Life Span Resistance 8 SPDT (4 x Form C and 4 x Form A) 120 VAC @ 0.5 A, or 30 VDC @ 1 A 8 ms max. 8 ms max. 1 x 107 operations Contact: 50 MW Insulation: 100 MW min.
Online Download www.advantech.com/products


▲Up To Search▲   

 
Price & Availability of PCLD-880

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X